Features & Benefits:
  • Motor: Series-wound DC motor. High efficiency reduces current draw at all conditions.
  • Pump: High-strength aluminium housing with steel gears and a seal protection feature that, in conjunction with a fuse, prevents motor or pump damage due to excessive pump pressure.
  • Timer/Wiring: Standard Prelub “no-delay” relay timer delivers fastest possible start and harness fuse.
  • Prevents harness and motor damage due to excessive current.
Specs:
  • 24 V
  • 30 to 120 ℓ
  • Motor Switch: Rated for 300 A continuous yet consumes minimal power for activation.
  • Inlet Hose: Rated for 91.44° C oil. Will not collapse under any vacuum level.
  • Pressure Hose: Rated for 91.44° C oil and 5 times maximum pump output pressure.
  • Check Valve: Prevents backflow of oil after engine start with minimal restriction & weight.
  • Standard Relief Valve (120 psi): Prevents pump damage.

Part No.: TP4K-40-24V
OE No.: 100524

Back
Product Disclaimer
  1. Although we have gone to great lengths to ensure all data was correct at the time of publishing, we cannot be held responsible for any consequential or any other damages whatsoever resulting from errors or omissions. It is up the individual purchasing or fitting the relative time to make sure that it is correct before wording or fitting the item. The time displayed might not always represent the manufacturer/system or item type that will be supplied for the relevant applications. All product information, manufacturer/OE names, part numbers and vehicle applications listed are used for reference purposes only.